Features:



  • Transformer with peak efficiency (96.0 %)

  • Wide operating temperature ranges: -25 °C to +60 °C

  • RS485 (EIA485) communication interfaces

  • Intelligent MPP tracking

  • Suitable for indoor and outdoor applications (IP65)

  • Simple and direct on-screen data display

  • 10 years standard guarantee

  • Compliant with low-voltage directive VDE AR N 4105 and mid-voltage directive BDEW

Delta Solivia 5,0 EU G4 TR

Dubbelklik op de afbeelding voor groot formaat

Uitzoomen
Inzoomen

Meer afbeeldingen

Details

Input (DC) Output (AC)
Max. recommended PV power 6000 WP (5320 WP DE / 5250 WP BE) Nominal apparent power 5000 VA 1) 3)
Nominal power 5500 W (4850 W DE / BE) Voltage range 184 ... 264 V 2)
Voltage range 125 ... 600 V Nominal current 22 A
Full power MPP range 150 ... 480 V Nominal frequency 50 Hz
Nominal current 15.7 A @ 350 V Frequency range 45 ... 65 Hz 2)
Max. current 36.6 A Power factor adjustable 0.8 cap ... 0.8 ind
Total harmonic distortion (THD) < 5 % @ nominal apparent power
General specification Mechanical design
Model name SOLIVIA 5.0 EU G4 TR 4) Size (L x W x D) 512 x 410 x 182 mm
Part number Delta EOE46010253 Weight 31 kg
Max. efficiency 96 % Cooling Convection
Efficiency EU 94.7 % AC connector Wieland RST25i3S
Operating temperature -25 ... +60 °C DC connector 3 pairs of Multi-Contact MC4
Full power without derating -25 ... +55 °C Communication interfaces 2 x RJ45 / RS485 + 1 x USB A
Storage temperature -25 ... +80 °C DC disconnector Integrated
Humidity 0 ... 95 % Display 3 LEDs, 4-line LCD
Max. operating altitude 2000 m (above sea level)
Standards Directives
Protection degree IP65 EMC EN61000-6-2;
Safety class I EN61000-6-3;
Configurable trip parameters Yes EN61000-3-11;
Insulation monitoring Yes EN61000-3-12
Overload behavior Current limitation; power limitation
Anti-islanding protection / Grid regulation DIN VDE 0126-1-1;
France/Islands (60 Hz);
RD 1699/2011; RD 661/2007
CEI0-21; Synergrid C10/11
(July 2012); EN 50438;
G59/1-2; VDE-AR-N 4105
Safety IEC62109-1 / -2

1) Cos Phi = 1 (VA = W)
2) AC voltage and frequency range will be programmed according to the individual country requirements.
3) Continuous nominal active power in the range of Cos Phi = 0.9 cap ... 0.9 ind
4) An overview of our inverters that can be installed in your country can be found on "Product availability".